by Sala, M. Moretti, Martel, K., Henriquet, C., Al Zein, A. and Simonelli, L., Sahle, Ch. J., Gonzalez, H., Lagier, M. -C. and Ponchut, C., Huotari, S., Verbeni, R., Krisch, M. and Monaco, G.
Abstract:
An end-station for resonant inelastic X-ray scattering and (resonant) X-ray emission spectroscopy at beamline ID20 of ESRF – The European Synchrotron is presented. The spectrometer hosts five crystal analysers in Rowland geometry for large solid angle collection and is mounted on a rotatable arm for scattering in both the horizontal and vertical planes. The spectrometer is optimized for high-energy-resolution applications, including partial fluorescence yield or high-energy-resolution fluorescence detected X-ray absorption spectroscopy and the study of elementary electronic excitations in solids. In addition, it can be used for non-resonant inelastic X-ray scattering measurements of valence electron excitations.
Reference:
A high-energy-resolution resonant inelastic X-ray scattering spectrometer at ID20 of the European Synchrotron Radiation Facility (Sala, M. Moretti, Martel, K., Henriquet, C., Al Zein, A. and Simonelli, L., Sahle, Ch. J., Gonzalez, H., Lagier, M. -C. and Ponchut, C., Huotari, S., Verbeni, R., Krisch, M. and Monaco, G.), In JOURNAL OF SYNCHROTRON RADIATION, INT UNION CRYSTALLOGRAPHY, volume 25, 2018.
Bibtex Entry:
@article{ ISI:000426315400035,
Author = {Sala, M. Moretti and Martel, K. and Henriquet, C. and Al Zein, A. and
Simonelli, L. and Sahle, Ch. J. and Gonzalez, H. and Lagier, M. -C. and
Ponchut, C. and Huotari, S. and Verbeni, R. and Krisch, M. and Monaco,
G.},
Title = {{A high-energy-resolution resonant inelastic X-ray scattering
spectrometer at ID20 of the European Synchrotron Radiation Facility}},
Journal = {{JOURNAL OF SYNCHROTRON RADIATION}},
Year = {{2018}},
Volume = {{25}},
Number = {{2}},
Pages = {{580-591}},
Month = {{MAR}},
Abstract = {{An end-station for resonant inelastic X-ray scattering and (resonant)
X-ray emission spectroscopy at beamline ID20 of ESRF - The European
Synchrotron is presented. The spectrometer hosts five crystal analysers
in Rowland geometry for large solid angle collection and is mounted on a
rotatable arm for scattering in both the horizontal and vertical planes.
The spectrometer is optimized for high-energy-resolution applications,
including partial fluorescence yield or high-energy-resolution
fluorescence detected X-ray absorption spectroscopy and the study of
elementary electronic excitations in solids. In addition, it can be used
for non-resonant inelastic X-ray scattering measurements of valence
electron excitations.}},
Publisher = {{INT UNION CRYSTALLOGRAPHY}},
Address = {{2 ABBEY SQ, CHESTER, CH1 2HU, ENGLAND}},
Type = {{Article}},
Language = {{English}},
Affiliation = {{Sala, MM (Corresponding Author), ESRF, European Synchrotron, 71 Ave Martyrs, F-38000 Grenoble, France.
Sala, M. Moretti; Martel, K.; Henriquet, C.; Al Zein, A.; Simonelli, L.; Sahle, Ch. J.; Gonzalez, H.; Lagier, M. -C.; Ponchut, C.; Huotari, S.; Verbeni, R.; Krisch, M.; Monaco, G., ESRF, European Synchrotron, 71 Ave Martyrs, F-38000 Grenoble, France.
Al Zein, A., Beirut Arab Univ, Dept Phys, Fac Sci, Beirut 11072809, Lebanon.
Simonelli, L., ALBA Synchrotron Light Facil, Carrer Llum 2-26, Barcelona 08290, Spain.
Huotari, S., Univ Helsinki, Dept Phys, POB 64, FI-00014 Helsinki, Finland.
Monaco, G., Univ Trento, Dipartimento Fis, Via Sommarive 14, I-38123 Povo, TN, Italy.}},
DOI = {{10.1107/S1600577518001200}},
ISSN = {{1600-5775}},
Keywords = {{resonant inelastic X-ray scattering; X-ray emission; ID20 beamline; RIXS
spectrometer; ESRF}},
Keywords-Plus = {{POSITION-SENSITIVE DETECTORS; ANALYZER CRYSTALS; L-3 EDGE; EXCITATIONS;
SUPERCONDUCTORS; RIXS; SPECTROSCOPY; SPECTRA}},
Research-Areas = {{Instruments & Instrumentation; Optics; Physics}},
Web-of-Science-Categories = {{Instruments & Instrumentation; Optics; Physics, Applied}},
Author-Email = {{marco.moretti@esrf.fr}},
ResearcherID-Numbers = {{Moretti, Marco/AAF-9255-2019
Zein, Ali Al/F-4393-2019
Krisch, Michael H/U-5662-2018
Monaco, Giulio/AAW-4387-2020
Sahle, Christoph/P-6715-2019
}},
ORCID-Numbers = {{Moretti, Marco/0000-0002-9744-9976
Krisch, Michael H/0000-0001-7423-1715
Monaco, Giulio/0000-0003-2497-6422
Sahle, Christoph/0000-0001-8645-3163
Huotari, Simo/0000-0003-4506-8722}},
Funding-Acknowledgement = {{ESRF}},
Funding-Text = {{We kindly acknowledge the ESRF for financing the UPBL6 project as part
of the ESRF Upgrade - Phase I. We also would like thank the ESRF for
support during the conception, design, construction and commissioning of
the spectrometer, specifically the TID and ISDD divisions.}},
Number-of-Cited-References = {{91}},
Times-Cited = {{27}},
Usage-Count-Last-180-days = {{1}},
Usage-Count-Since-2013 = {{32}},
Journal-ISO = {{J. Synchrot. Radiat.}},
Doc-Delivery-Number = {{FX8BL}},
Unique-ID = {{ISI:000426315400035}},
OA = {{Other Gold, Green Published}},
DA = {{2020-12-22}},
}
Comments are closed